A Way to Improve User Experience in Complicated Applications in LabVIEW

LabVIEW 8.x comes with the User Interface Event Handler template by default to process user interface events. But in some complicated applications, there will be so many jobs to do at the same time, and this default template is not enough. For example, in one of my projects, UUT’s power supply monitor and serial communication with UUT is running all the time while some tests are performed. If only with the default template in this case, the user interface will freeze when the application is performing some time-consuming jobs like serial communication or DAQ.